Fusion Operation
The Fusion environment can be configured and used to create, visualize and
track Trouble Calls, Outage and Incident information right on top of the
distribution network data stored in its database. This information can be
represented as a schematic network as well as a geographic network, and both
representations can be viewed simultaneously in different Fusion viewers.
Combined with Fusion Theme Editor, it is possible to display load summary,
color by feeder, mainline and dashboard-type view themes.
The Outage Reporting system is used to provide Management and staff with a
thorough understanding of any distribution network deficiencies encountered
in the past. By tracking outages, it is possible to establish which lines or
network segments gave the most reliability issues.
Tracks network reliability using SAIDI, SAIFI, CAIDI, MAIFI and ASAI indices
.
Each of these indices are derived statistics from the
collection of outage data input into the reporting system from the field.
SAIDI is
the reliability index most electric utilities are graded on.
This particular index relates to the length or duration of outages expressed
in
hours.
The compilation of data calculated into these indices gives us the
ability: To report to the Public Utilities Commissions;
Report to management and senior staff; Generate responses to complaints
and determine if complaints are valid. Further more, by tracking outage
causes, it is possible to
determine what network improvements are required to increase feeder and
substation reliability.
Key features
- Visualize Trouble Call, Outage and Incident
- Create What if Scenario
- Schematic and Geographic views
Modules
Network
editor
Create your Switching What If scenario, De energize, Cut, Connect,
change the state of your network, are one of the various task you can
accomplished using the Editor.
View
datasheet
Network
viewer
Fusion Viewer render spatial data from spatial RDBMS. It's
configurable symbology with complex sub-part symbol allows you to
visualize your GIS data in any possible ways.
The Network Viewer can be configure to automatically load the GIS
data within the boundary of the viewer’s viewport, or to rely on the
user to manually load the desired data. This flexibility allows you
to optimize performances and business processes when working in a
specific geographic area.
Background information can be displayed through the use of graphical
files such as DXF or DWG files.
View
datasheet
Network
Analysis
Network Analysis is used to analyse the connectivity status of the
equipment—channels and devices—that make up the distribution network
of
your organization. This analysis is done by running a trace, which
displays the connectivity of a network by means of a highlighting
effect.
Within a localized network, a trace can be as short or as long as you
want.
This is because Network Analysis allows you to select a place in the
network
that will serve as the starting point of a trace and to select other
places that
will serve as the ending points, also called breaking or break
points.
Instead of using break points, however, other methods are available
to limit
the extent of a trace. For example, you can run a trace on a
particular phase,
or you can let a trace run until the sum of a certain attribute
equals a
pre-identified value, or you can cause a break to occur when the
trace
encounters the first instance of a particular type of entity or a
particular class
of entities.
View
datasheet
LineView
LineView™ is a .NET™ based software solution that analyses the
connectivity database and entity components of a circuit, then
produces an electrical tree-diagram specified by the user. This
result is dynamic in that LineView can be re-run at any time and
specifically after circuit corrections or switching operations.
What are the Benefits of Using LineView™?
-
Users have the ability to electrically
analyze actual distribution circuits with a display
result of their choice.
-
Phase, de-energized entities, parallel loops
and missing attribute data are easily recognized by
color.
-
Load transfer affects of Switching Operations
can be predicted and demonstrated visually.
-
Temporary restoration switching affects can
be predicted.
-
Circuit Tie Switches can be quickly located
and identified.
-
Network data mapping corrections
can be quickly verified.
View datasheet
Theme
editor
Theme Editor is a Fusion™ plug-in that enables the user community to
define thematic views of the Fusion database content, based on the
needs of each user group. Defined thematic views are available to be
used with all Fusion plug-ins installed on any given Fusion
workstation.
View
datasheet
Reporting
Reporting is a module that allows you write, share and run queries on
your data to validate and to interogate the content of your Fusion
GIS database. The results can be displayed in a viewer, a tabular
grid, a browser or exported in other data formats to view them
externally.
Here is a short list of data analysis where Fusion Reporting delivers
exceptional results:
- Connectivity anomaly detection (Parallel feed, loops,
de-energized sections, phase dégradation conditions, etc.)
- Feature relationships analysis (customer to transformer,
overhead equipment to pole, underground equipment to vault,
etc.)
- Construction standards analysis (overhead to underground
connections, wire size and connected equipment, equipment type
and pole class, invalid span length, etc.)
- Spatial analysis (invalid equipment placement, overlapping
feature detection, etc.)
- Other data quality verifications (missing mandatory values,
incompatible attribute values, missing mandatory annotations,
etc.)
Fusion being based on Oracle Spatial, you have access to all the
Oracle spatial functions to analyse your data.
View datasheet